19. In the Fault dialog, do the following:
a. Select the Enable Positive Software Limit Detection check
box, and then type 24
b. Select the Enable Negative Software Limit Detection
check box, and then type 0
c. Select the Enable Maximum Position Error Detection
check box.
d. In the Maximum Positive Position Error box, type 0.2
e. In the Maximum Negative Position Error box, type –0.2
f. Click Next.
20. In the Dedicated I/O dialog, do the following:
a. In the Input Type list, select Onboard Input 2 and then
click Positive Limit.
b. In the Input Type list, select Onboard Input 3 and then
click Negative Limit.
c. Click Next.
Axis 2
21. In the Axis 2 dialog box, do the following:
a. In the Axis Name (Alias) box, type Z
b. In the Command Output list select DAC 2.
c. Click Next.
22. In the Drive/Motor dialog, click Next.
23. In the Feedback dialog, click Next.
24. In the Scaling dialog, do the following:
a. Under Specify Units, click Inches.
b. In the Transmission list, select Leadscrew
c. In the Transmission Details box (below the Transmission
list), type 0.2—This represents the number of inches per
revolution of the leadscrew.
d. Click Next.