Parker Hannifin
28 Programmer’s Guide
Hardware Configuration
Before using an ACR controller, you must define for the firmware
what specific hardware is installed. The default configuration is as
follows:
CONFIG ENC8 DAC4 DAC4 ADC8
The command uses four arguments— encoders, module 0, module 1,
and module 2.
Encoder: The encoder argument is the number of encoder channels
installed.
NONE, ENC2, ENC4, ENC6, ENC8, ENC10
Module 0: The module 0 argument is the type of module installed in
the first SIMM socket.
NONE, DAC2, DAC4, STEPPER2, STEPPER4, DACSTEP2, DACSTEP4
Module 1: The module 1 argument is the type of module installed in
the second SIMM socket.
NONE, DAC2, DAC4, STEPPER2, STEPPER4
Module 2: The module 2 argument is indicates whether an ADC
module is installed in the third SIMM socket.
NONE, ADC8
In ACR-View, the New Controller Wizard determines the CONFIG
statement for you.
Defining Hardware Configuration
► To define the hardware, use the CONFIG command.
Reviewing Your Configuration
► To view the current configuration, enter CONFIG with no
arguments.