System Configuration 39
Memory Allocations
Memory allocation on the ACR series controllers is completely
customizable —you can assign controller memory to features and
functions that need it most for your particular application. Using the
Configuration Wizard, you can quickly allocate memory for the
following: programs, PLCs, global variables, local variables, arrays,
and communication stream buffers.
It is important to dimension the memory correctly for your
application. The factory default memory allocations are limited to
programs, which receive 512K. The communication stream buffers
receive 256 bytes each.
Once you have allocated memory for a program, PLC, or global
variables, you cannot change it without first clearing the memory
space (CLEAR command). Otherwise, you receive a “Re-
dimensioned block” error.
NOTE: The controller stores system memory in battery-backed
SRAM, as well as hardware configuration data. If you reset
memory using the BRESET command, memory allocation
returns to factory settings.
Caution — When you send the BRESET command, you cannot
return the battery to normal operation without removing and
then restoring power. Stored programs are lost during the power
restore.